http://dbpedia.org/resource/Partial_stroke_testing
http://dbpedia.org/ontology/abstract Partial stroke testing (or PST) is a technPartial stroke testing (or PST) is a technique used in a control system to allow the user to test a percentage of the possible failure modes of a shut down valve without the need to physically close the valve. PST is used to assist in determining that the safety function will operate on demand. PST is most often used on high integrity emergency shutdown valves (ESDVs) in applications where closing the valve will have a high cost burden yet proving the integrity of the valve is essential to maintaining a safe facility. In addition to ESDVs PST is also used on high integrity pressure protection systems or HIPPS. Partial stroke testing is not a replacement for the need to fully stroke valves as proof testing is still a mandatory requirement. testing is still a mandatory requirement.
http://dbpedia.org/ontology/wikiPageExternalLink https://www.neles.com/products/valve-controllers/neles-valvguard-vg9000--intelligent-safety-solenoid/ + , http://www.rotork.com/en/product/index/svm + , http://www.valcontrols.com/ + , http://www.isa.org/ + , http://www.netherlocks.com/partial-stroke-testing/netherlocks-develops-remote-operation-for-faith-pst-system/ + , http://www.iec.ch/ + , http://www.ascendant-technologies.com/ + , https://web.archive.org/web/20121229082755/http:/www.paladonsystems.com/index.php/products/pst-controller + , http://www.dynatorque.com/dstop/ + , http://www.imi-precision.com/ico4-pst + , http://www.foxboro-eckardt.com/en-gb/products/control-valve-positioners/srd991/ +
http://dbpedia.org/ontology/wikiPageID 28381575
http://dbpedia.org/ontology/wikiPageLength 12369
http://dbpedia.org/ontology/wikiPageRevisionID 1031034881
http://dbpedia.org/ontology/wikiPageWikiLink http://dbpedia.org/resource/Markov_analysis + , http://dbpedia.org/resource/Shut_down_valve + , http://dbpedia.org/resource/Category:Safety_engineering + , http://dbpedia.org/resource/Safety_life_cycle + , http://dbpedia.org/resource/Category:Safety_equipment + , http://dbpedia.org/resource/Programmable_logic_controller + , http://dbpedia.org/resource/Failure_mode_and_effects_analysis + , http://dbpedia.org/resource/Hazard_and_operability_study + , http://dbpedia.org/resource/Instrument_Society_of_Automation + , http://dbpedia.org/resource/Fault_tree_analysis + , http://dbpedia.org/resource/Redundancy_%28engineering%29 + , http://dbpedia.org/resource/Safety_integrity_level + , http://dbpedia.org/resource/Flow_control_valve + , http://dbpedia.org/resource/Solenoid_valve + , http://dbpedia.org/resource/Petroleum_industry + , http://dbpedia.org/resource/International_Electrotechnical_Commission + , http://dbpedia.org/resource/IEC61511 + , http://dbpedia.org/resource/American_National_Standards_Institute + , http://dbpedia.org/resource/IEC61508 + , http://dbpedia.org/resource/Predictive_maintenance + , http://dbpedia.org/resource/Category:Valves +
http://dbpedia.org/property/wikiPageUsesTemplate http://dbpedia.org/resource/Template:Reflist +
http://purl.org/dc/terms/subject http://dbpedia.org/resource/Category:Safety_equipment + , http://dbpedia.org/resource/Category:Valves + , http://dbpedia.org/resource/Category:Safety_engineering +
http://purl.org/linguistics/gold/hypernym http://dbpedia.org/resource/Technique +
http://www.w3.org/ns/prov#wasDerivedFrom http://en.wikipedia.org/wiki/Partial_stroke_testing?oldid=1031034881&ns=0 +
http://xmlns.com/foaf/0.1/isPrimaryTopicOf http://en.wikipedia.org/wiki/Partial_stroke_testing +
owl:sameAs http://yago-knowledge.org/resource/Partial_stroke_testing + , https://global.dbpedia.org/id/fCfE + , http://rdf.freebase.com/ns/m.0crfp3j + , http://www.wikidata.org/entity/Q17074068 + , http://dbpedia.org/resource/Partial_stroke_testing +
rdf:type http://dbpedia.org/class/yago/Thing100002452 + , http://dbpedia.org/class/yago/PhysicalEntity100001930 + , http://dbpedia.org/class/yago/BodyPart105220461 + , http://dbpedia.org/class/yago/WikicatValves + , http://dbpedia.org/class/yago/Part109385911 + , http://dbpedia.org/class/yago/Valve105395286 + , http://dbpedia.org/ontology/TopicalConcept + , http://dbpedia.org/class/yago/Structure105225602 +
rdfs:comment Partial stroke testing (or PST) is a technPartial stroke testing (or PST) is a technique used in a control system to allow the user to test a percentage of the possible failure modes of a shut down valve without the need to physically close the valve. PST is used to assist in determining that the safety function will operate on demand. PST is most often used on high integrity emergency shutdown valves (ESDVs) in applications where closing the valve will have a high cost burden yet proving the integrity of the valve is essential to maintaining a safe facility. In addition to ESDVs PST is also used on high integrity pressure protection systems or HIPPS. Partial stroke testing is not a replacement for the need to fully stroke valves as proof testing is still a mandatory requirement. testing is still a mandatory requirement.
rdfs:label Partial stroke testing
hide properties that link here 
http://dbpedia.org/resource/PST + http://dbpedia.org/ontology/wikiPageDisambiguates
http://dbpedia.org/resource/Partial_stroke_test + http://dbpedia.org/ontology/wikiPageRedirects
http://dbpedia.org/resource/Shut_down_valve + , http://dbpedia.org/resource/PST + , http://dbpedia.org/resource/Partial_stroke_test + , http://dbpedia.org/resource/Partial_valve_stroke_testing + http://dbpedia.org/ontology/wikiPageWikiLink
http://en.wikipedia.org/wiki/Partial_stroke_testing + http://xmlns.com/foaf/0.1/primaryTopic
http://dbpedia.org/resource/Partial_stroke_testing + owl:sameAs
 

 

Enter the name of the page to start semantic browsing from.